KP / KPI Pressure switches from -0.2bar to 28bar
- Adjustable Differential settings from 0.4bar to 6bar
- Enclosure IP30, IP44
- Wide setting range
- Small dimensions. Space saving – easy to install in panels
RT Pressure switches from -1bar to 30bar
- Adjustable Differential settings from 0.09bar to 4bar
- Enclosure IP66
- Long operation life time
- High accuracy, High repeatability
- Available with all major marine approvals
- Flame proof switches available
KPS Pressure switches from 0bar to 60bar
- A high level of enclosure IP67
- Adjustable differential
- Robust and compact construction
- Resistance to shock and vibration
- Available with all major marine approvals
MBC compact Pressure switches from -0.2bar to 400bar
- Enclosure IP65. with all major ship approvals.
- High repeatability
- Applications: Can be used for pumps, compressors, hydraulic oil and general purpose applications
Temperature Switches
KP Temperature switches from 0'c to 150'c
- Enclosure IP30, IP44
- Adjustable differential setting
RT Temperature switches from 25'c to 300'c
- Enclosure IP66
- Adjustable differential setting
- Capaillary tube with 2m, 3m, 5m & 8m
KPS Temperature switches from -10'c to 200'c
- Enclosure IP67
- Adjustable differential setting
- Capaillary (Armoured) tube with 2m, 3m, 5m & 8m & Rigid sensor
Differential Pressure Switches
RT Differential Pressure switches from 0bar to 11bar
- Enclosure IP66
- Fixed differential setting
Pressure Transmitters
MBS3000
- Enslosure and wetted parts of acid-resistant stainless steel (AISI 316L)
- Pressure ranges in relative (gauge) or absolute from 0 up to 600 bar
- All standard output signals: 4 - 20 mA, 0 - 5 V, 1 - 5 V, 1 - 6 V, 0 - 10 V, 1 - 10 V
- A wide range of pressure and electrical connections
- Temperature compensated and laser calibrated
Versions also available with pulsesnubber. Resistant to cavitation, liquid hammer and pressure peaks
- Different Models available
- with up to 125'c
- with O/p 4 – 20 mA, absolute voltage, ratiometric output
- with Zero Point & Span adjustment
- with +/-0.3 to 1% Accuracy
- with High PT range 0-2200bar
- Versions with Ex Zone 0 approval available
- with Enclosure IP65 & IP67
- with High degree of EMC/EMI protection
- "Low Pressure ranges 40mbar to 250mbar as well as
bidirectional (flexible zero point) e.g. -70 to 70 mbar or
-20 to 80 mbar etc."
- The high accuracy flush diaphragm pressure transmitter MBS 4510 is designed for use in non-uniform, high viscous or crystallizing media within industrial applications, and offers a reliable pressure measurement, even under harsh environmental conditions. Ranges from 0-0.25bar to 0-25bar ZP &SA with 4-20mA
- Applications: Water Pumps, Air Compressors, Powerpacks, Fuel treatment, Engines, Gear boxes, Propulsion systems, Boilers and general purpose applications
Temperature Sensors
MBT3560
- Compact design with built-in 4-20mA transmitter
- Corrosion resistant stainless steel AISI 316 Ti sensor
- High vibration resistant
- Measuring range 0 to 200°C
- Insertion depth: 50mm, 100mm, 150mm, 200mm, 250mm, 300mm & 395mm
MBT3270
- Ultra compact construction
- High vibration resistant
- Also available with KTY sensing element
- Process connection G1/4A & M10x1
- Sensor element: KTY, Pt 100, Pt 1000, NTC/PTC
- Insertion depth: 24mm, 28mm, 32mm, 40mm, 50mm
MBT5310
- For monitoring of bearing temperatures where there is risk of overheating, in applications such as Wind Turbines, Engines & Gear boxes
- Up to 200 °C
- Sensing element Pt 100 or Pt 1000
- Spring loaded to ensure excellent contact to bearing
MBT153 with Sensor Pocket MBT120
- universal cable temperature sensor that can be used for controlling cooling water and ventilation systems within general industry applications.
- Temperature range -50 – 200 °C
- Short response times
- Pt 100 or Pt 1000 resistance element
- 2- or 4-wire connection
- MBT 120 sensor pocket available
- Sensor Pocket Insertion depth: 50mm, 100mm, 150mm, 200mm
- The sensor combined with the sensor pocket is named MBT5253.
Solenoid Valves
servo operated 2/2way solenoid valve, type EV220A
- Compact solenoid valve for robust industrial applications
- For water, oil, compressed air and similar neutral media
- NO version, standard for 1/4” to 1” valve sizes
- NC version, standard for 1/4” to 2” valve sizes
- Liquid hammer damped
- Low power consumption
- Differential pressure: 0.2 to 16 bar
- Viscosity: Up to 50 cSt
- Ambient temperatures: Up to +50°C
- Media temperatures: -30 to 100°C
- Enclosure: Up to IP 65
- Coil options with 230Vac / 24Vdc / 24Vac / 110Vac / 12Vdc
servo operated 2/2way solenoid valve for Steam, type EV225B
- The design is based on PTFE diaphragm concept, ensuring highly reliable function even in connection with contaminated steam.
- Specifically designed for steam applications, 160 °C or 185 °C
- Flow range: 0.9 – 6.0 m3/h
- Differential pressure: 0.2 – 10 bar
- Media temperature from 0 – 185 °C
- Ambient temperature: up to 40 °C
- Coil enclosure: up to IP65
- Thread connections: from G 1/4 to G 1 ISO 228/1. Only NC versions
- "Valve body in dezincification resistant brass and valve seats
made in stainless steel for ensuring a long life even in connection
with aggressive steam media."
- Coil options with 230Vac / 24Vac / 110Vac
servo operated 2/2way solenoid valve, type EV220B
- Compact solenoid valve for robust industrial applications
EV220B 6-22
- For water, oil, compressed air and similar neutral media
- G1/4 – G1 connection ISO228/1
- Flow range from 0.2 – 19 m³/h
- Differential pressure from 0.1 – 30 bar
- Media temperature from -30 – 100 °C
- Ambient temperature: Up to 80 °C
- Coil enclosure: Up to IP67
- Thread connections: From G ¼ – G 1
- Viscosity: Up to 50 cSt
- Brass version NC and NO
- DZR brass version NC
- FKM and EPDM
- Also available with NPT thread
EV220B 15-50
- For water, steam, oil, compressed air and gases
- Flow range for water: 1.3 – 160 m³/h
- Differential pressure: 0.3 – 16 bar
- Media temperature from -30 – 140 °C
- Ambient temperature: Up to 80 °C
- Coil enclosure: Up to IP67
- Thread connections: From G ½ – G 2
- Viscosity: Up to 50 cSt
- Water hammer damped
- Built in filter for protection of pilot system
- Adjustable closing time available
- EV220B NC and NO brass version for neutral liquids and gasses
- EV220BD NC DZR version for neutral and slightly aggressive liquids and gases
- EV220BSS NC Stainless steel version for neutral and aggressive liquids and gases
- Also available with NPT thread.
EV220B 65-100
- use in robust industrial applications, demanding high flow rates.
- The valve is designed with cast iron valve body and flanged connection.
- For water and similar neutral media
- Flow range for water: 25 – 400 m³/h
- Ambient temperature: Up to 80 °C
- Differential pressure: Up to 10 bar
- Viscosity: Up to 50 cSt
- Coil enclosure: Up to IP67
- Flange connections: 2 1/2, 3 and 4”
- Water hammer damped
- Built-in filter for protection of pilot system
- Seal material: EPDM and NBR
Externally-operated valves, type AV210 (Angle Seat valves)
- AV210 is an externally operated valve can operate at very high medium temperatures and viscosities, and is insensitive to dirt particles in the medium; thus, it is often called a “troubleshooter” valve.
- For all fluids and gases
- Flow range: 0 – 234 m3/h
- Differential pressure: 0 – 16 bar
- Medium temperature: -30 – 180 °C
- Ambient temperature: -30 – 60 °C
- Thread connection: G 3⁄8 – G 2 in (NC and NO)
- Orifice size: DN 15 – 50 mm
- Unpressurized closed (NC) bidirectional versions
- unpressurized opened (NO) version closing against the flow direction
- NC version: bi-directional, closing against or closing with the flow direction
- NO version: always closing against the flow direction
Thermostatically operated valves, type AVTA
- "Thermo. operated water valves are used for
proportional regulation of flow quantity,
depending on the setting and the sensor
temperature."
- Insensitive to dirt & Insensitive to water pressure
- Self-acting – no power needed
- Opens on rising sensor temperature
- Differential pressure 0 – 10 bar
- Cooling Media temperature -25 to 130 °C
- Thread connection G 3⁄8 – G 1
- The valves are pressure-relieved, i.e. the degree
- The regulation range is defined for the point at which the valve begins to open.